Mts Series 793 Application Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Mts Series 793 Application. MTS Series 793 Application User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 576
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
be certain.
m
MTS Model 793.10 MultiPurpose TestWare
®
and
Series 793 Application Software
100-147-131 H
User Information and Software Reference for Model 793.10
MultiPurpose TestWare
and the following:
- Model 793.11 Profile Editor™
- Model 793.12 Trend Monitoring
- Model 793.14 Fatigue Monitoring
- Model 793.71 Time History Playout
- Model 793.72 THP with Acquisition
Przeglądanie stron 0
1 2 3 4 5 6 ... 575 576

Podsumowanie treści

Strona 1 - 100-147-131 H

be certain.mMTS Model 793.10 MultiPurpose TestWare® and Series 793 Application Software100-147-131 HUser Information and Software Reference for Model

Strona 2

MTS MultiPurpose TestWare®Technical Support10Identify system type To enable the Call Center agent to connect you with the most qualified technical sup

Strona 3

MTS MultiPurpose TestWare®About Group Process InterruptsWorking with MPT Processes100About Group Process InterruptsNormal interrupt Group processes ha

Strona 4

About Group Process InterruptsMTS MultiPurpose TestWare® Working with MPT Processes101If neither the Cyclic or Segment processes have an interrupt sel

Strona 5

MTS MultiPurpose TestWare®About Group Process InterruptsWorking with MPT Processes102In this case, when the Group is interrupted, the following things

Strona 6 - Index 567

How to Disable ProcessesMTS MultiPurpose TestWare® Working with MPT Processes103How to Disable ProcessesYou can disable a process in the following way

Strona 7

MTS MultiPurpose TestWare®How to Disable ProcessesWorking with MPT Processes104

Strona 8 - Before You Contact MTS

MTS MultiPurpose TestWare® Working with MPT Variables105Chapter 9 Working with MPT VariablesContents About MPT Variables 106About Variable Operatio

Strona 9 - If You Contact MTS by Phone

MTS MultiPurpose TestWare®About MPT VariablesWorking with MPT Variables106About MPT VariablesThe MPT Variables feature is a keyed option that equips t

Strona 10 - Technical Support

About Variable OperationMTS MultiPurpose TestWare® Working with MPT Variables107About Variable Operation“Fixed” parameters Normally, when a procedure

Strona 11

MTS MultiPurpose TestWare®About Creating Variables with Multiple Associated Working with MPT Variables108About Creating Variables with Multiple Associ

Strona 12

About Variables and the Operator InformationMTS MultiPurpose TestWare® Working with MPT Variables109About Variables and the Operator Information Proce

Strona 13 - Before You Begin

MTS MultiPurpose TestWare® Technical Support11Access the Problem Submittal Form:• In the back of many MTS manuals (postage paid form to be mailed to M

Strona 14 - Conventions

MTS MultiPurpose TestWare®About Variables and the Operator Information Working with MPT Variables110When you run the test, a run-time window that allo

Strona 15 - Electronic manual

About Variables and the Operator InformationMTS MultiPurpose TestWare® Working with MPT Variables111You use the Variable Editor to associate parameter

Strona 16

MTS MultiPurpose TestWare®About Calculated VariablesWorking with MPT Variables112About Calculated Variables You can modify the value of any numeric va

Strona 17 - About MultiPurpose TestWare

Test Design Considerations for Adding CalculationsMTS MultiPurpose TestWare® Working with MPT Variables113Test Design Considerations for Adding Calcul

Strona 18 - Application Overview

MTS MultiPurpose TestWare®About Control-Mode VariablesWorking with MPT Variables114About Control-Mode VariablesA control-mode variable is an enumerati

Strona 19 - About MPT Processes

About the Variable EditorMTS MultiPurpose TestWare® Working with MPT Variables115Variable EditorAbout the Variable EditorYou use the Variable Editor t

Strona 20 - Test Procedures in Projects

MTS MultiPurpose TestWare®About the Variable EditorWorking with MPT Variables116Variable types The variable type determines the type of data associate

Strona 21 - About the MPT User Interface

About the Variable EditorMTS MultiPurpose TestWare® Working with MPT Variables117Example of variables inthe Variable Editor In this example, “category

Strona 22

MTS MultiPurpose TestWare®About Calculations and the Variables EditorWorking with MPT Variables118About Calculations and the Variables Editor“Calculat

Strona 23

About Creating and Editing VariablesMTS MultiPurpose TestWare® Working with MPT Variables119About Creating and Editing VariablesTo create and edit var

Strona 24

MTS MultiPurpose TestWare®Technical Support12

Strona 25 - About the MPT Control Panel

MTS MultiPurpose TestWare®How to Create, Edit, Assign, and Unassign Working with MPT Variables120How to Create, Edit, Assign, and Unassign Variables w

Strona 26 - MPT Control Panel Toolbar

How to Create a Variable with the Make ToolMTS MultiPurpose TestWare® Working with MPT Variables121How to Create a Variable with the Make Tool1. Open

Strona 27

MTS MultiPurpose TestWare®How to Add a Calculation to a Variable with the Working with MPT Variables122How to Add a Calculation to a Variable with the

Strona 28 - MPT Test Progress Panel

How to Add a Calculation to a Variable with theMTS MultiPurpose TestWare® Working with MPT Variables123How to Add a Calculation to a Variable with the

Strona 29 - MPT Specimen Panel

MTS MultiPurpose TestWare®How to Add a Calculation to a Variable with the Working with MPT Variables124

Strona 30

MTS MultiPurpose TestWare® Working with MPT Specimens125Chapter 10 Working with MPT SpecimensContents About MPT Specimens 127About Assigning MPT Sp

Strona 31 - MPT Power Panel

MTS MultiPurpose TestWare®Working with MPT Specimens126Procedure Has Been Modified and Run Against the MPT Specimen Without Being Saved 149Procedur

Strona 32 - MPT Channel Counters Panel

About MPT SpecimensMTS MultiPurpose TestWare® Working with MPT Specimens127About MPT SpecimensAn MPT specimen contains a number of files associated wi

Strona 33 - MPT Sequence Counters Panel

MTS MultiPurpose TestWare®How to Create and Link a New MPT Specimen with Working with MPT Specimens128MPT specimens are automatically linked to the cu

Strona 34 - About Process Specific Panels

How to Create and Link a New MPT Specimen withMTS MultiPurpose TestWare® Working with MPT Specimens129How to Create and Link a New MPT Specimen with t

Strona 35 - MPT Run/Stop/Hold Panel

MTS MultiPurpose TestWare® Preface13PrefaceBefore You BeginSafety first! Before you use your MTS product or system, read and understand the Safety man

Strona 36 - MPT Procedure Editor

MTS MultiPurpose TestWare®About Runing Multiple Tests Against the Same MPT Working with MPT Specimens1305. In the Load Specimen window, click Procedur

Strona 37 - Display Menu

MPT Specimen EditorMTS MultiPurpose TestWare® Working with MPT Specimens131MPT Specimen EditorUse the MPT Specimen Editor to create, edit, and delete

Strona 38 - MPT Procedure Editor Toolbar

MTS MultiPurpose TestWare®MPT Specimen EditorWorking with MPT Specimens132 Procedure Path/ File NameDisplays the procedure associated with the selecte

Strona 39

MPT Specimen EditorMTS MultiPurpose TestWare® Working with MPT Specimens133For more information For more information about placeholders, see “About pl

Strona 40 - Procedure Table

MTS MultiPurpose TestWare®MPT Specimen File TypesWorking with MPT Specimens134MPT Specimen File TypesAbout MPT FilesThe number of files (and the conte

Strona 41

About Specimen.dat FilesMTS MultiPurpose TestWare® Working with MPT Specimens135See “About Specimen.mps Files” on page 139.See “About Specimen.prm Fil

Strona 42 - Process Palette

MTS MultiPurpose TestWare®About Specimen.dat FilesWorking with MPT Specimens136How to format the datain the MPT specimendata fileYou can configure the

Strona 43 - Performing Common Tasks

How to Create User-Specified.dat FilesMTS MultiPurpose TestWare® Working with MPT Specimens137For more information For more information, see “How to C

Strona 44 - How to Create a New Procedure

MTS MultiPurpose TestWare®About Specimen.log FilesWorking with MPT Specimens138About Specimen.log Files The Specimen.log file contains the contents of

Strona 45

About Specimen.mps FilesMTS MultiPurpose TestWare® Working with MPT Specimens139About Specimen.mps FilesThe Specimen.mps file is a recovery file used

Strona 46 - Design elements that

MTS MultiPurpose TestWare®ConventionsPreface14ConventionsDocumentation ConventionsThe following paragraphs describe some of the conventions that are u

Strona 47 - How to Print a Procedure

MTS MultiPurpose TestWare®About Loading MPT SpecimensWorking with MPT Specimens140About Loading MPT SpecimensIf you select an MPT specimen that MPT ha

Strona 48 - How to Run a Procedure

About the Load Procedure SelectionsMTS MultiPurpose TestWare® Working with MPT Specimens141To see how these selections are used in specific situations

Strona 49 - Types of Counters

MTS MultiPurpose TestWare®About the Restore Procedure State SelectionsWorking with MPT Specimens142See “About the Restore Procedure State Selections”

Strona 50

MPT Specimen Loading ExamplesMTS MultiPurpose TestWare® Working with MPT Specimens143MPT Specimen Loading ExamplesThe following examples are provided

Strona 51 - Sequence Counters

MTS MultiPurpose TestWare®Procedure Has Not Been Run Against the MPT Working with MPT Specimens144Procedure Has Not Been Run Against the MPT SpecimenS

Strona 52

Procedure Has Been Run Against the MPTMTS MultiPurpose TestWare® Working with MPT Specimens145Procedure Has Been Run Against the MPT SpecimenSuppose y

Strona 53 - Use the right-mouse

MTS MultiPurpose TestWare®Procedure Has Been Run Against the MPT Working with MPT Specimens146Example Suppose that in this scenario the test was inter

Strona 54

Procedure Has Been Run Against the MPTMTS MultiPurpose TestWare® Working with MPT Specimens147The MPT specimen now contains information (test data, lo

Strona 55

MTS MultiPurpose TestWare®Procedure Has Been Run Against the MPT Working with MPT Specimens148Procedure Has Been Run Against the MPT Specimen, Modifie

Strona 56

Procedure Has Been Modified and Run Against theMTS MultiPurpose TestWare® Working with MPT Specimens149Restore procedurestate toSince the MPT specimen

Strona 57 - About the MPT Specimen Log

ConventionsMTS MultiPurpose TestWare® Preface15Illustrations Illustrations appear in this manual to clarify text. They are examples only and do not ne

Strona 58

MTS MultiPurpose TestWare®Procedure Has Been Modified and Run Against the Working with MPT Specimens150Currently loadedprocedureMPT unlinks the MPT sp

Strona 59

Procedure Has Been Modified, Run Against the MPTMTS MultiPurpose TestWare® Working with MPT Specimens151Procedure Has Been Modified, Run Against the M

Strona 60 - Scroll to new entry

MTS MultiPurpose TestWare®Procedure Has Been Modified, Run Against the Working with MPT Specimens152This version of procedure “def.000” includes the m

Strona 61 - MPT Options Editor

MTS MultiPurpose TestWare® Creating a Practice Test Procedure153Chapter 11 Creating a Practice Test ProcedureThis section describes how to create a pr

Strona 62 - About the MPT Options Editor

MTS MultiPurpose TestWare®Plan Your TestCreating a Practice Test Procedure154Plan Your TestTo plan your test, you should:• Identify test objectives an

Strona 63

Plan Your TestMTS MultiPurpose TestWare® Creating a Practice Test Procedure155C. Monitor the physical specimen’s internal breakwire for continuity, an

Strona 64

MTS MultiPurpose TestWare®Determine Which Processes Are NeededCreating a Practice Test Procedure156Determine Which Processes Are NeededA process is a

Strona 65

Determine Which Processes Are NeededMTS MultiPurpose TestWare® Creating a Practice Test Procedure157How these processesworkThe following illustrates S

Strona 66

MTS MultiPurpose TestWare®Determine Which Processes Are NeededCreating a Practice Test Procedure158Example of a groupprocess at workThe following illu

Strona 67

Determine Which Processes Are NeededMTS MultiPurpose TestWare® Creating a Practice Test Procedure159Note The process diagram below shows the procedure

Strona 68

MTS MultiPurpose TestWare®ConventionsPreface16

Strona 69

MTS MultiPurpose TestWare®Determine Which Processes Are NeededCreating a Practice Test Procedure160An alternate method—building and testingfunctional

Strona 70 - About Transition States

Add Processes to the Procedure TableMTS MultiPurpose TestWare® Creating a Practice Test Procedure161Otherwise, you can still benefit by reading about

Strona 71

MTS MultiPurpose TestWare®Add Processes to the Procedure TableCreating a Practice Test Procedure1623. Add the remaining processes to the procedure tab

Strona 72 - Program States

Sequence Your ProcessesMTS MultiPurpose TestWare® Creating a Practice Test Procedure163E. Add a Data Limit Detector process and name it Trigger at 50C

Strona 73 - Data File

MTS MultiPurpose TestWare®Sequence Your ProcessesCreating a Practice Test Procedure164B. Observe that the Start trigger for the Ramp to Mean process i

Strona 74

Sequence Your ProcessesMTS MultiPurpose TestWare® Creating a Practice Test Procedure1653. Specify a “Procedure is done when” trigger.Set the Procedure

Strona 75 - About Test Recovery

MTS MultiPurpose TestWare®Set Process Parameters in the Procedure TableCreating a Practice Test Procedure166Note This Group is done when trigger selec

Strona 76 - Recovery

Set Process Parameters in the Procedure TableMTS MultiPurpose TestWare® Creating a Practice Test Procedure1672. Define the Cyclic Command (Fatigue Par

Strona 77 - Message Capture

MTS MultiPurpose TestWare®Set Process Parameters in the Procedure TableCreating a Practice Test Procedure1683. Define the second Segment Command proce

Strona 78

Set Process Parameters in the Procedure TableMTS MultiPurpose TestWare® Creating a Practice Test Procedure1694. Define the Peak/Valley Data Acquisitio

Strona 79

MTS MultiPurpose TestWare® About MultiPurpose TestWare17Chapter 5 About MultiPurpose TestWareContents About MTS MultiPurpose TestWare (MPT) 18About

Strona 80

MTS MultiPurpose TestWare®Set Process Parameters in the Procedure TableCreating a Practice Test Procedure1705. Define the Digital Input process (Monit

Strona 81

Set Process Parameters in the Procedure TableMTS MultiPurpose TestWare® Creating a Practice Test Procedure1716. Define the Group (Fan Control) process

Strona 82

MTS MultiPurpose TestWare®Set Process Parameters in the Group TableCreating a Practice Test Procedure172Set Process Parameters in the Group Table1. Di

Strona 83

Set Process Parameters in the Group TableMTS MultiPurpose TestWare® Creating a Practice Test Procedure1733. Define the Digital Output (Switch Fan On)

Strona 84

MTS MultiPurpose TestWare®Set Process Parameters in the Group TableCreating a Practice Test Procedure1744. Define the second Data Limit Detector proce

Strona 85 - Insertion

Set Process Parameters in the Group TableMTS MultiPurpose TestWare® Creating a Practice Test Procedure1755. Define the second Digital Output process (

Strona 86

MTS MultiPurpose TestWare®Select Procedure OptionsCreating a Practice Test Procedure176Select Procedure OptionsYou can use the MPT Options Editor to s

Strona 87 - About Sequencing Processes

Select Procedure OptionsMTS MultiPurpose TestWare® Creating a Practice Test Procedure177B. Type text as desired in the Description box to describe the

Strona 88

MTS MultiPurpose TestWare®Select Procedure OptionsCreating a Practice Test Procedure178

Strona 89 - About “Buffer Full” Signals

MTS MultiPurpose TestWare® Command Processes179Chapter 12 Command ProcessesCommand Process Types ICON PROCESS NAME DESCRIPTIONSegment Command ProcessP

Strona 90 - About “Trigger” Signals

MTS MultiPurpose TestWare®Application OverviewAbout MultiPurpose TestWare18Application OverviewAbout MTS MultiPurpose TestWare (MPT)MTS Model 793.10 M

Strona 91

MTS MultiPurpose TestWare®Command Processes180Note If a command process includes both normal (high-rate) and low rate channels, the channels will star

Strona 92

Segment Command ProcessMTS MultiPurpose TestWare® Command Processes181Segment Command ProcessAbout the Segment Command ProcessThe Segment Command proc

Strona 93 - Process Sequence Example

MTS MultiPurpose TestWare®Segment Command ProcessCommand Processes182Segment Command Parameter DescriptionsCommand tabCommand Tab (part 1 of 2)ITEM D

Strona 94 - About Editing Trigger Signals

Segment Command ProcessMTS MultiPurpose TestWare® Command Processes183Channels tab Displays the channels available to this process. Use the arrow keys

Strona 95

MTS MultiPurpose TestWare®Segment Command ProcessCommand Processes184How to Define a Segment Command Process1. Drag the icon from the Process Palett

Strona 96

Segment Command ProcessMTS MultiPurpose TestWare® Command Processes18520. Optional—If you enabled a counter, type a Counter Label.21. Set the desired

Strona 97

MTS MultiPurpose TestWare®Cyclic Command ProcessCommand Processes186Cyclic Command ProcessAbout the Cyclic Command ProcessThe Cyclic Command process d

Strona 98 - Sequence processes

Cyclic Command ProcessMTS MultiPurpose TestWare® Command Processes187Cycles and segments You can repeat cycles or segments. Two segments create one cy

Strona 99 - How to Open the Group Table

MTS MultiPurpose TestWare®Cyclic Command ProcessCommand Processes188Example Assume a cyclic command completes its process at End Level 2 (in this case

Strona 100

Cyclic Command ProcessMTS MultiPurpose TestWare® Command Processes189Tapered wave shapes You specify the beginning and ending taper times on the Comma

Strona 101 - User-defined interrupt

Application OverviewMTS MultiPurpose TestWare® About MultiPurpose TestWare19About MPT ProcessesWhen you create tests with the MPT application, you use

Strona 102

MTS MultiPurpose TestWare®Cyclic Command ProcessCommand Processes190True sine tapered This true sine wave tapers from 0% to 100% amplitude at the begi

Strona 103 - How to Disable Processes

Cyclic Command ProcessMTS MultiPurpose TestWare® Command Processes191Cyclic Command Parameter DescriptionsCommand tabCommand Tab (part 1 of 2)ITEM DES

Strona 104 - Working with MPT Processes

MTS MultiPurpose TestWare®Cyclic Command ProcessCommand Processes192General tabChannels tab Displays the channels available to this process. Use the a

Strona 105 - Working with MPT Variables

Cyclic Command ProcessMTS MultiPurpose TestWare® Command Processes193How to Define a Cyclic Command Process1. Drag the icon from the Process Palette

Strona 106 - About MPT Variables

MTS MultiPurpose TestWare®Cyclic Command ProcessCommand Processes19417. Click the General tab.18. In the Name box, type a name for this process. (You

Strona 107 - About Variable Operation

Dwell Command ProcessMTS MultiPurpose TestWare® Command Processes195Dwell Command ProcessAbout the Dwell Command ProcessThe Dwell Command process is a

Strona 108 - Variable Editor

MTS MultiPurpose TestWare®Dwell Command ProcessCommand Processes196General tabChannels tabDisplays the channels available to this process. Use the arr

Strona 109 - Operator Information

Dwell Command ProcessMTS MultiPurpose TestWare® Command Processes197How to Define a Dwell Command Process1. Drag the icon from the Process Palette t

Strona 110

MTS MultiPurpose TestWare®Profile ProcessCommand Processes198Profile ProcessAbout the Profile ProcessThe Profile process generates a command based on

Strona 111

Profile ProcessMTS MultiPurpose TestWare® Command Processes199About Working with DimensionsWhen you use the Profile Editor application to assign dimen

Strona 112 - About Calculated Variables

MTS MultiPurpose TestWare®Copyright information © 2011 MTS Systems Corporation. All rights reserved.Trademark information MTS, FlexTest, RPC, Temposon

Strona 113 - Calculations created

MTS MultiPurpose TestWare®Application OverviewAbout MultiPurpose TestWare20Test Procedures in ProjectsA Project is a folder that contains or reference

Strona 114 - About Control-Mode Variables

MTS MultiPurpose TestWare®Profile ProcessCommand Processes200Next, select the Multipurpose TestWare application, then open the MPT Procedure Editor (i

Strona 115

Profile ProcessMTS MultiPurpose TestWare® Command Processes201Using the same profile, suppose you change the Control Mode selection to force, and type

Strona 116 - Default variable naming

MTS MultiPurpose TestWare®Profile ProcessCommand Processes202Profile Command Parameter DescriptionsCommand tabAbout selectingreferenced filesProfile,

Strona 117 - Example of variables in

Profile ProcessMTS MultiPurpose TestWare® Command Processes203When defining these processes, you must specify the desired external program file in the

Strona 118 - “Calculated” checkbox

MTS MultiPurpose TestWare®Profile ProcessCommand Processes204For more information about editing Project Settings files, see the MTS 793 Control Softwa

Strona 119

Profile ProcessMTS MultiPurpose TestWare® Command Processes205Mapping tabMapping TabITEM DESCRIPTIONChannelDisplays all station control channels.Profi

Strona 120

MTS MultiPurpose TestWare®Profile ProcessCommand Processes206Actions tabFile Summary tabAction TabITEM DESCRIPTIONNameDisplays the name of the action

Strona 121

Profile ProcessMTS MultiPurpose TestWare® Command Processes207General tabFor more information For information on creating profiles with the Profile Ed

Strona 122

MTS MultiPurpose TestWare®Profile ProcessCommand Processes208How to Define a Profile Command Process1. Drag the icon from the Process Palette to you

Strona 123

Profile ProcessMTS MultiPurpose TestWare® Command Processes209Note The Execute Process value multiplies the Total Passes in the Command parameters. If

Strona 124

The MultiPurpose TestWare InterfaceMTS MultiPurpose TestWare® About MultiPurpose TestWare21The MultiPurpose TestWare InterfaceAbout the MPT User Inter

Strona 125 - Working with MPT Specimens

MTS MultiPurpose TestWare®Profile ProcessCommand Processes210Note Only one Profile process with manual compensation may run at a time. Note Setpoint a

Strona 126 - Saved 151

External Command ProcessMTS MultiPurpose TestWare® Command Processes211External Command ProcessAbout the External Command ProcessThe External Command

Strona 127 - About Assigning MPT Specimens

MTS MultiPurpose TestWare®External Command ProcessCommand Processes212About Starting External CommandsIf the external command is not running when MPT

Strona 128 - Using the Specimen

External Command ProcessMTS MultiPurpose TestWare® Command Processes213and when the MPT Setpoint option (MPT Options Editor > Execution > Setpoi

Strona 129 - With the Specimen

MTS MultiPurpose TestWare®External Command ProcessCommand Processes214About Setpoint/Span SettingsYou can also define a different setpoint and span to

Strona 130

External Command ProcessMTS MultiPurpose TestWare® Command Processes215About Overriding System Setpoint and SpanWith the External Command process, you

Strona 131 - MPT Specimen Editor

MTS MultiPurpose TestWare®External Command ProcessCommand Processes216External Command Parameter DescriptionsScaling tabScaling Tab (part 1 of 2)ITEM

Strona 132 - TEM DESCRIPTION

External Command ProcessMTS MultiPurpose TestWare® Command Processes217General tabChannels tabDisplays the channels available to this process. Use the

Strona 133

MTS MultiPurpose TestWare®External Command ProcessCommand Processes218How to Define an External Command Process1. Drag the icon from the Process Pal

Strona 134 - MPT Specimen File Types

External Command ProcessMTS MultiPurpose TestWare® Command Processes21919. In the Execute Process box, type the number of times you want the process t

Strona 135 - About Specimen.dat Files

MTS MultiPurpose TestWare®The MultiPurpose TestWare InterfaceAbout MultiPurpose TestWare22MPT control panel The MPT control panel appears in the appli

Strona 136 - How to parse the MPT

MTS MultiPurpose TestWare®Sweep Command ProcessCommand Processes220Sweep Command ProcessAbout the Sweep ActivityWith the Sweep activity you can sweep

Strona 137

Sweep Command ProcessMTS MultiPurpose TestWare® Command Processes221Cycles and segments You can repeat cycles or segments. Two segments create one cyc

Strona 138 - About Specimen.mpp Files

MTS MultiPurpose TestWare®Sweep Command ProcessCommand Processes222Sweep Command Parameter DescriptionsCommand tabCommand Tab (part 1 of 2)ITEM DESCRI

Strona 139 - About Specimen.prm Files

Sweep Command ProcessMTS MultiPurpose TestWare® Command Processes223General tabChannels tabDisplays the channels available to this process. Use the ar

Strona 140 - About Loading MPT Specimens

MTS MultiPurpose TestWare®Sweep Command ProcessCommand Processes224How to Define a Sweep Process1. Drag the icon from the Process Palette to your gr

Strona 141

Sweep Command ProcessMTS MultiPurpose TestWare® Command Processes22517. Click the General tab.18. In the Name box, type a name for this process. (You

Strona 142

MTS MultiPurpose TestWare®Signal Based Command ProcessCommand Processes226Signal Based Command ProcessAbout the Signal Based Command (SBC) ProcessThis

Strona 143 - MPT Specimen Loading Examples

Signal Based Command ProcessMTS MultiPurpose TestWare® Command Processes227Signal Based Command (SBC) Process ExampleIn the example below, the SBC loo

Strona 144 - Procedure assigned to

MTS MultiPurpose TestWare®Signal Based Command ProcessCommand Processes228Signal Based Command (SBC) Lookup-Table File RequirementsFile format The SBC

Strona 145 - IALOG ITEM DEFAULT

Signal Based Command ProcessMTS MultiPurpose TestWare® Command Processes229Signal Based Command (SBC) Process Parameter DescriptionsNote The SBC proce

Strona 146 - Relinked to Another Procedure

The MultiPurpose TestWare InterfaceMTS MultiPurpose TestWare® About MultiPurpose TestWare23Procedure Editor The Procedure Editor contains a table on w

Strona 147

MTS MultiPurpose TestWare®Signal Based Command ProcessCommand Processes230Mapping tab The Mapping tab allows you to specify SBC parameters for each co

Strona 148

Signal Based Command ProcessMTS MultiPurpose TestWare® Command Processes231General tabHow to Create a Signal Based Command (SBC) Process1. Drag the SB

Strona 149 - Restore procedure

MTS MultiPurpose TestWare®Signal Based Command ProcessCommand Processes2325. Click the Command tab.A. Click Lookup Table Path/File to define the file

Strona 150

Profile with ALC ProcessMTS MultiPurpose TestWare® Command Processes233Profile with ALC ProcessAbout the Profile with ALC ProcessThe Profile with ALC

Strona 151

MTS MultiPurpose TestWare®Profile with ALC ProcessCommand Processes234Command tabCommand TabITEM DESCRIPTIONProfile Path/FileSpecifies the profile fil

Strona 152

Profile with ALC ProcessMTS MultiPurpose TestWare® Command Processes235Mapping tabMapping TabITEM DESCRIPTIONChannelDisplays all station control chann

Strona 153 - Chapter 11

MTS MultiPurpose TestWare®Profile with ALC ProcessCommand Processes236Actions tabFile summary tabAction TabITEM DESCRIPTIONNameDisplays the name of th

Strona 154 - Plan Your Test

Profile with ALC ProcessMTS MultiPurpose TestWare® Command Processes237Matrix tab Note This tab is enabled only if ALC has been selected as the Adapti

Strona 155 - The sample test

MTS MultiPurpose TestWare®Profile with ALC ProcessCommand Processes238Verify Loaded Matrix ParametersSpecifies whether you want the application to com

Strona 156

Profile with ALC ProcessMTS MultiPurpose TestWare® Command Processes239Tracking tabFor more information For more information, see “About Specimen.mps

Strona 157 - How these processes

MTS MultiPurpose TestWare®The MultiPurpose TestWare InterfaceAbout MultiPurpose TestWare24Process Palette The processes available are displayed on the

Strona 158 - Example of a group

MTS MultiPurpose TestWare®Profile with ALC ProcessCommand Processes2409. For each station channel, select a Control Mode and optionally, a Level Multi

Strona 159

Cyclic with ALC ProcessMTS MultiPurpose TestWare® Command Processes241Cyclic with ALC ProcessAbout the Cyclic with ALC ProcessThe Cyclic with ALC proc

Strona 160

MTS MultiPurpose TestWare®Cyclic with ALC ProcessCommand Processes242Command tabChannels tabDisplays the channels available to this process. Use the a

Strona 161

Cyclic with ALC ProcessMTS MultiPurpose TestWare® Command Processes243Matrix tabMatrix Tab (part 1 of 2)ITEM DESCRIPTIONCompensation Matrix NameNames

Strona 162

MTS MultiPurpose TestWare®Cyclic with ALC ProcessCommand Processes244Tracking tabNumber of CellsSpecifies the number of cells in each axis of the matr

Strona 163 - Sequence Your Processes

Cyclic with ALC ProcessMTS MultiPurpose TestWare® Command Processes245How to Define a Cyclic with ALC Process1. Drag the icon from the Process Palet

Strona 164

MTS MultiPurpose TestWare®Cyclic with ALC ProcessCommand Processes24620. Under Matrix Parameters, configure your ALC matrix.21. Optional—If you want t

Strona 165

Model 793.71/72 Time History Output ProcessMTS MultiPurpose TestWare® Command Processes247Model 793.71/72 Time History Output ProcessAbout the Time Hi

Strona 166

MTS MultiPurpose TestWare®Model 793.71/72 Time History Output ProcessCommand Processes2485. Select one of the following from the dropdown menu:About T

Strona 167 - (Fatigue Part)

Model 793.71/72 Time History Output ProcessMTS MultiPurpose TestWare® Command Processes249Time History Output Status WindowNote This panel appears onl

Strona 168 - (Return to Zero)

The MultiPurpose TestWare InterfaceMTS MultiPurpose TestWare® About MultiPurpose TestWare25About the MPT Control PanelWith the MPT control panel you c

Strona 169 - (Acquire Peak/Valley)

MTS MultiPurpose TestWare®Model 793.71/72 Time History Output ProcessCommand Processes250Time History Output Parameter DescriptionsCommand tabCommand

Strona 170 - (Monitor Continuity)

Model 793.71/72 Time History Output ProcessMTS MultiPurpose TestWare® Command Processes251You may make limited changes to the contents of an RPC time

Strona 171

MTS MultiPurpose TestWare®Model 793.71/72 Time History Output ProcessCommand Processes252Drive has an offsetWhen enabled and relative mode is not sele

Strona 172 - (Trigger at 75C)

Model 793.71/72 Time History Output ProcessMTS MultiPurpose TestWare® Command Processes253Mapping tab Important If you map an RPC Pro drive file (.seq

Strona 173 - (Switch Fan On)

MTS MultiPurpose TestWare®Model 793.71/72 Time History Output ProcessCommand Processes254Enable AIC CompensatorsEnables the Adaptive Inverse Control (

Strona 174 - (Trigger at 50C)

Model 793.71/72 Time History Output ProcessMTS MultiPurpose TestWare® Command Processes255Actions tabAction TabITEM DESCRIPTIONNameDisplays the names

Strona 175 - (Switch Fan Off)

MTS MultiPurpose TestWare®Model 793.71/72 Time History Output ProcessCommand Processes256Acquisition tab Note This tab appears only if you have purcha

Strona 176 - Select Procedure Options

Model 793.71/72 Time History Output ProcessMTS MultiPurpose TestWare® Command Processes257Trend tab Note This tab appears only if you have purchased t

Strona 177

MTS MultiPurpose TestWare®Model 793.71/72 Time History Output ProcessCommand Processes258General tabHow to Define a Time History Output Process1. Drag

Strona 178

Model 793.71/72 Time History Output ProcessMTS MultiPurpose TestWare® Command Processes2599. Use the File Channel and Station Channel lists to map the

Strona 179 - Command Processes

MTS MultiPurpose TestWare®The MultiPurpose TestWare InterfaceAbout MultiPurpose TestWare26MPT Control Panel ToolbarThe buttons that comprise the MPT c

Strona 180

MTS MultiPurpose TestWare®Model 793.71/72 Time History Output ProcessCommand Processes26023. Optional—Map station actions to drive file sequences.24.

Strona 181 - Segment Command Process

Road Surface Output ProcessMTS MultiPurpose TestWare® Command Processes261Road Surface Output ProcessAbout the Road Surface Output ProcessNote This pr

Strona 182 - Command tab

MTS MultiPurpose TestWare®Road Surface Output ProcessCommand Processes262With RSURF you can nest files up to four levels. The following diagram shows

Strona 183 - General tab

Road Surface Output ProcessMTS MultiPurpose TestWare® Command Processes263Road Surface Output Parameter DescriptionsCommand tabCommand Tab (part 1 of

Strona 184

MTS MultiPurpose TestWare®Road Surface Output ProcessCommand Processes264Relative Time SignalIf selected, the process reads the current command value

Strona 185

Road Surface Output ProcessMTS MultiPurpose TestWare® Command Processes265Mapping tabMapping Tab (part 1 of 2)ITEM DESCRIPTIONFile Channel/Descriptor/

Strona 186 - Cyclic Command Process

MTS MultiPurpose TestWare®Road Surface Output ProcessCommand Processes266Enable AIC CompensatorsEnables the Adaptive Inverse Control (AIC) compensatio

Strona 187

Road Surface Output ProcessMTS MultiPurpose TestWare® Command Processes267Actions tabStatus tabAction TabITEM DESCRIPTIONNameDisplays the names of the

Strona 188 - Segment Shapes

MTS MultiPurpose TestWare®Road Surface Output ProcessCommand Processes268General tabHow to Define a Road Surface Output Process1. Drag the icon from

Strona 189

Road Surface Output ProcessMTS MultiPurpose TestWare® Command Processes2699. Use the File Channel and Station Channel lists to map the drive file chan

Strona 190

The MultiPurpose TestWare InterfaceMTS MultiPurpose TestWare® About MultiPurpose TestWare27For more information See “MPT Specimen Editor” on page 131.

Strona 191

MTS MultiPurpose TestWare®Road Surface Output ProcessCommand Processes270

Strona 192

MTS MultiPurpose TestWare® Data Acquisition Process Descriptions271Chapter 13 Data Acquisition Process DescriptionsUse data acquisition processes to a

Strona 193

MTS MultiPurpose TestWare®Data Acquisition Process Descriptions272Note There is a slight time delay between processes that start with a common trigger

Strona 194

MTS MultiPurpose TestWare® Data Acquisition Process Descriptions273Data File HeaderThe first line of the data file includes information like the decim

Strona 195 - Dwell Command Process

MTS MultiPurpose TestWare®Data Acquisition Process Descriptions274How to Trigger a Process When the Buffer Is FullBy using the trigger or buffer full

Strona 196 - Channels tab

MTS MultiPurpose TestWare® Data Acquisition Process Descriptions275When you run this test, the Peak/Valley Data Acquisition process will be triggered

Strona 197

MTS MultiPurpose TestWare®Data Acquisition Process Descriptions276About Station SignalsThe following signals are available to the MultiPurpose TestWar

Strona 198 - Profile Process

MTS MultiPurpose TestWare® Data Acquisition Process Descriptions277Interlock, Run/Stop, Hold, Program Interlock, HSM On, HSM HighRecords the binary st

Strona 199 - About Working with Dimensions

MTS MultiPurpose TestWare®Data Acquisition Process Descriptions278Time and RolloverTime signalsTime and Running Time signals are useful for recording

Strona 200

Peak/Valley Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions279Peak/Valley Acquisition ProcessAbout Peak/Valley Pro

Strona 201

MTS MultiPurpose TestWare®The MultiPurpose TestWare InterfaceAbout MultiPurpose TestWare28MPT Test Progress PanelThe Test Progress panel displays the

Strona 202 - About selecting

MTS MultiPurpose TestWare®Peak/Valley Acquisition ProcessData Acquisition Process Descriptions280Peak/Valley Acquisition Parameter DescriptionsAcquisi

Strona 203 - Editing placeholder

Peak/Valley Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions281List Filter With the List Filter, you can pare the l

Strona 204 - Compatibility between

MTS MultiPurpose TestWare®Peak/Valley Acquisition ProcessData Acquisition Process Descriptions282Output units tabFor more informationSee “About Buffer

Strona 205 - Mapping tab

Peak/Valley Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions28311. In the Destination list, click the destination f

Strona 206 - File Summary tab

MTS MultiPurpose TestWare®Timed Acquisition ProcessData Acquisition Process Descriptions284Timed Acquisition ProcessAbout the Timed Acquisition Proces

Strona 207

Timed Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions285General tabSignals tab Selects signals from which this pro

Strona 208

MTS MultiPurpose TestWare®Timed Acquisition ProcessData Acquisition Process Descriptions286Destination tabOutput units tabFor more information See “Ab

Strona 209 - How to apply manual

Timed Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions287See “About Station Signals” on page 276.How to Define a Ti

Strona 210 - Adjusted values not

MTS MultiPurpose TestWare®Timed Acquisition ProcessData Acquisition Process Descriptions28811. In the Buffer Type list, click the buffer type.12. Opti

Strona 211 - External Command Process

Max/Min Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions289Max/Min Acquisition ProcessAbout the Max/Min Acquisition

Strona 212 - Command process

The MultiPurpose TestWare InterfaceMTS MultiPurpose TestWare® About MultiPurpose TestWare29MPT Specimen PanelThe Specimen panel displays the current M

Strona 213

MTS MultiPurpose TestWare®Max/Min Acquisition ProcessData Acquisition Process Descriptions290Max/Min Acquisition Parameter DescriptionsAcquisition tab

Strona 214 - About Setpoint/Span Settings

Max/Min Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions291General tabSignals Tab Selects signals from which this p

Strona 215

MTS MultiPurpose TestWare®Max/Min Acquisition ProcessData Acquisition Process Descriptions292Destination tabNote Buffer settings, Discard Data options

Strona 216 - Scaling tab

Max/Min Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions293For more information See “About Buffers” on page 272.See

Strona 217

MTS MultiPurpose TestWare®Max/Min Acquisition ProcessData Acquisition Process Descriptions294How to Define a Max/Min Acquisition Process1. Drag the

Strona 218

Max/Min Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions29510. Optional—Click the Output Units tab.Change the unit

Strona 219

MTS MultiPurpose TestWare®Level Crossing Acquisition ProcessData Acquisition Process Descriptions296Level Crossing Acquisition ProcessAbout the Level

Strona 220 - Sweep Command Process

Level Crossing Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions297Level Crossing Acquisition Parameter Descriptions

Strona 221

MTS MultiPurpose TestWare®Level Crossing Acquisition ProcessData Acquisition Process Descriptions298For example, typing force displays all signals tha

Strona 222

Level Crossing Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions299Output units tabFor more information See “About B

Strona 223

MTS MultiPurpose TestWare® Contents3Technical Support 7Preface 13Conventions 14Chapter 5 About MultiPurpose TestWare 17Application Overvie

Strona 224 - How to Define a Sweep Process

MTS MultiPurpose TestWare®The MultiPurpose TestWare InterfaceAbout MultiPurpose TestWare30For more information For more information about MPT specimen

Strona 225

MTS MultiPurpose TestWare®Level Crossing Acquisition ProcessData Acquisition Process Descriptions30010. Type the Buffer Size and type a description of

Strona 226 - Signal Based Command Process

High Speed Timed Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions301High Speed Timed Acquisition ProcessAbout the H

Strona 227

MTS MultiPurpose TestWare®High Speed Timed Acquisition ProcessData Acquisition Process Descriptions302Keep in mind that the actual sample duration (an

Strona 228

High Speed Timed Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions303494 hardware sampleratesThe following sample ra

Strona 229

MTS MultiPurpose TestWare®High Speed Timed Acquisition ProcessData Acquisition Process Descriptions304• 2048 System Rate:• 1024 System Rate:MAXIMUM SA

Strona 230

High Speed Timed Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions305MAXIMUM SAMPLE RATE MAXIMUM NUMBER OF SIGNALS10

Strona 231

MTS MultiPurpose TestWare®High Speed Timed Acquisition ProcessData Acquisition Process Descriptions306High Speed Timed Acquisition Parameter Descripti

Strona 232

High Speed Timed Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions307Note If the Time signal is selected, data is ge

Strona 233 - Profile with ALC Process

MTS MultiPurpose TestWare®High Speed Timed Acquisition ProcessData Acquisition Process Descriptions308Note Discard Data options are not available for

Strona 234

High Speed Timed Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions3095. In the Sample Duration box, specify the leng

Strona 235

The MultiPurpose TestWare InterfaceMTS MultiPurpose TestWare® About MultiPurpose TestWare31MPT Power PanelThe Power panel displays the hydraulic suppl

Strona 236 - File summary tab

MTS MultiPurpose TestWare®Cyclic Acquisition ProcessData Acquisition Process Descriptions310Cyclic Acquisition ProcessAbout the Cyclic Acquisition Pro

Strona 237

Cyclic Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions311In this case, the cyclic acquisition process will not tri

Strona 238

MTS MultiPurpose TestWare®Cyclic Acquisition ProcessData Acquisition Process Descriptions312Cyclic Acquisition Parameter DescriptionsData Storage tabD

Strona 239 - Tracking tab

Cyclic Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions313Acquisition tabStore Data AtDisplays which cycles or segm

Strona 240

MTS MultiPurpose TestWare®Cyclic Acquisition ProcessData Acquisition Process Descriptions314Signals tab Selects signals from which this process acquir

Strona 241 - Cyclic with ALC Process

Cyclic Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions315Note Buffer settings are not available for the Cyclic Dat

Strona 242

MTS MultiPurpose TestWare®Cyclic Acquisition ProcessData Acquisition Process Descriptions316For more information See “About Buffers” on page 272.See “

Strona 243 - Matrix tab

Cyclic Acquisition ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions317How to Define a Cyclic Acquisition Process1. Drag the i

Strona 244

MTS MultiPurpose TestWare®Cyclic Acquisition ProcessData Acquisition Process Descriptions318Note The order of the signals in the Included list determi

Strona 245

Fatigue ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions319Fatigue ProcessAbout the Fatigue ProcessThe Fatigue process accumula

Strona 246

MTS MultiPurpose TestWare®The MultiPurpose TestWare InterfaceAbout MultiPurpose TestWare32MPT Channel Counters PanelThe Channel Counters panel display

Strona 247

MTS MultiPurpose TestWare®Fatigue ProcessData Acquisition Process Descriptions320About Rainflow Counting and HistogramsRainflow counting Rainflow coun

Strona 248 - YSTEM RATE (HZ)FILE RATE (HZ)

Fatigue ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions321RangeMean histogram The RangeMean histogram identifies the range and

Strona 249

MTS MultiPurpose TestWare®Fatigue ProcessData Acquisition Process Descriptions322MinMax histogram The MinMax histogram identifies the rainflow-counted

Strona 250

Fatigue ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions323Range histogram This method identifies cycles only by the cycle rang

Strona 251 - Relative Time Signal

MTS MultiPurpose TestWare®Fatigue ProcessData Acquisition Process Descriptions324Number of bins The number of bins specifies the number of bins betwee

Strona 252

Fatigue ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions325Signals tabSignals TabITEM DESCRIPTIONSignalsDisplays the signals wh

Strona 253

MTS MultiPurpose TestWare®Fatigue ProcessData Acquisition Process Descriptions326Monitoring tabMonitoring TabITEM DESCRIPTIONTime Interval (secs)Speci

Strona 254

Fatigue ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions327Settings tabSettings TabITEM DESCRIPTIONMaterial LibrarySpecifies a

Strona 255

MTS MultiPurpose TestWare®Fatigue ProcessData Acquisition Process Descriptions328General tabFor more informationSee “About Buffers” on page 272.See “A

Strona 256

Fatigue ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions329Note You can use the Trend process in parallel with the Fatigue proc

Strona 257 - Status tab

The MultiPurpose TestWare InterfaceMTS MultiPurpose TestWare® About MultiPurpose TestWare33MPT Sequence Counters PanelThe Sequence Counters panel disp

Strona 258 - 8. Click the Mapping tab

MTS MultiPurpose TestWare®Fatigue ProcessData Acquisition Process Descriptions33016. Set the desired Start and Interrupt signals for the process in th

Strona 259

Time History Input ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions331Time History Input ProcessAbout the Time History Input Pr

Strona 260

MTS MultiPurpose TestWare®Time History Input ProcessData Acquisition Process Descriptions332Time History Input Parameter DescriptionsFile tabFile TabI

Strona 261 - Road Surface Output Process

Time History Input ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions333Channels tabGeneral tabFor more informationSee “About Buf

Strona 262

MTS MultiPurpose TestWare®Time History Input ProcessData Acquisition Process Descriptions334How to Define a Time History Input Process1. Drag the ic

Strona 263

Time History Input ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions33518. Select the Process Enabled check box. (If this box is

Strona 264

MTS MultiPurpose TestWare®Trend ProcessData Acquisition Process Descriptions336Trend ProcessAbout the Trend ProcessThe Trend process collects signal d

Strona 265

Trend ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions337Example You could monitor strain levels in a critical component of the

Strona 266

MTS MultiPurpose TestWare®Trend ProcessData Acquisition Process Descriptions338Trend Parameter DescriptionsTrend tabTrend TabITEM DESCRIPTIONData File

Strona 267

Trend ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions339Signals tabMonitoring tabSignals TabITEM DESCRIPTIONSignal NamesDispla

Strona 268

MTS MultiPurpose TestWare®The MultiPurpose TestWare InterfaceAbout MultiPurpose TestWare34About Process Specific PanelsProcess specific panels display

Strona 269

MTS MultiPurpose TestWare®Trend ProcessData Acquisition Process Descriptions340General tabFor more informationSee “About Buffers” on page 272.See “Abo

Strona 270

Trend ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions341Note If desired, you can use the Fatigue process in parallel with the

Strona 271 - Chapter 13

MTS MultiPurpose TestWare®Trend ProcessData Acquisition Process Descriptions342Important hints • If your procedure runs for a long time, make sure the

Strona 272 - About Buffers

Trend ProcessMTS MultiPurpose TestWare® Data Acquisition Process Descriptions343To achieve this, use a Group process with a repeat count of 20. (If yo

Strona 273 - Data File Header

MTS MultiPurpose TestWare®Trend ProcessData Acquisition Process Descriptions344

Strona 274

MTS MultiPurpose TestWare® Event Process Descriptions345Chapter 14 Event Process DescriptionsYou use event processes to monitor test signals and issue

Strona 275 - Data Destination

MTS MultiPurpose TestWare®Data Limit Detector ProcessEvent Process Descriptions346Data Limit Detector ProcessAbout Data Limit Detector ProcessThe Data

Strona 276 - About Station Signals

Data Limit Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions347About Limit ModesThis process supports relative limits (starting wh

Strona 277 - TEM DESCRIDESCRIPTIONPTION

MTS MultiPurpose TestWare®Data Limit Detector ProcessEvent Process Descriptions348Data Limit Detector Parameter DescriptionsLimits tabSignals tabSelec

Strona 278 - Time signals

Data Limit Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions349Log Message AsAssigns a severity level to the message (in ascending

Strona 279 - About Peak/Valley Process

The MultiPurpose TestWare InterfaceMTS MultiPurpose TestWare® About MultiPurpose TestWare35MPT Run/Stop/Hold PanelThe run/stop/hold panel controls run

Strona 280 - Acquisition tab

MTS MultiPurpose TestWare®Data Limit Detector ProcessEvent Process Descriptions350Limit table tab The Limit Table tab displays all the limits defined

Strona 281 - Destination tab

Data Limit Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions351General tabFor more information See “About Limit Modes” on page 347

Strona 282 - For more information

MTS MultiPurpose TestWare®Data Limit Detector ProcessEvent Process Descriptions3527. Click the Settings tab.8. Under Limit Mode, set the limit mode.9.

Strona 283

Digital Input Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions353Digital Input Detector ProcessAbout the Digital Input Detector P

Strona 284 - Timed Acquisition Process

MTS MultiPurpose TestWare®Digital Input Detector ProcessEvent Process Descriptions354Design considerations If the signal is high when the process begi

Strona 285

Digital Input Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions355Settings tabSettings Tab (part 1 of 2)ITEM DESCRIPTIONTrigger M

Strona 286

MTS MultiPurpose TestWare®Digital Input Detector ProcessEvent Process Descriptions356General tabFor more informationSee “How to set signal options” on

Strona 287

Digital Input Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions357For more information about triggers, see “About Sequencing Proce

Strona 288

MTS MultiPurpose TestWare®Digital Input Detector ProcessEvent Process Descriptions35818. Set the desired Start and Interrupt signals for the process i

Strona 289 - Max/Min Acquisition Process

Operator Event ProcessMTS MultiPurpose TestWare® Event Process Descriptions359Operator Event ProcessAbout the Operator Event ProcessThe Operator Event

Strona 290

MTS MultiPurpose TestWare®MPT Procedure EditorAbout MultiPurpose TestWare36MPT Procedure EditorAbout the MPT Procedure EditorThe MPT Procedure Editor

Strona 291

MTS MultiPurpose TestWare®Operator Event ProcessEvent Process Descriptions360Operator Event Parameter DescriptionsSettings tabSettings TabITEM DESCRIP

Strona 292 - Output Units Tab

Operator Event ProcessMTS MultiPurpose TestWare® Event Process Descriptions361Options tabOptions Tab ITEM DESCRIPTIONTrigger ModeTrigger Once causes t

Strona 293

MTS MultiPurpose TestWare®Operator Event ProcessEvent Process Descriptions362General tabFor more informationFor more information about triggers, see “

Strona 294

Operator Event ProcessMTS MultiPurpose TestWare® Event Process Descriptions363How to Define an Operator Event Process1. Drag the icon from the Proce

Strona 295

MTS MultiPurpose TestWare®Peak/Valley Change Detector ProcessEvent Process Descriptions364Peak/Valley Change Detector ProcessAbout the Peak/Valley Cha

Strona 296 - Level crossing

Peak/Valley Change Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions365Sensitivity A sensitivity value specifies how much the sign

Strona 297 - Signals Tab

MTS MultiPurpose TestWare®Peak/Valley Change Detector ProcessEvent Process Descriptions366If you do not use Channel Reference, the process will begin

Strona 298

Peak/Valley Change Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions367Peak/Valley Change Detector Process ExampleSuppose you want

Strona 299

MTS MultiPurpose TestWare®Peak/Valley Change Detector ProcessEvent Process Descriptions368Peak/Valley Change Detector Parameter DescriptionsSettings t

Strona 300

Peak/Valley Change Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions369Log Message AsAssigns a severity level to the message (in a

Strona 301 - Sample rate and

MPT Procedure EditorMTS MultiPurpose TestWare® About MultiPurpose TestWare37MPT Procedure Editor MenuThe following menus are available on the MPT Proc

Strona 302 - 493 hardware sample

MTS MultiPurpose TestWare®Peak/Valley Change Detector ProcessEvent Process Descriptions370Command tabGeneral tabCommand TabITEM DESCRIPTIONChannel Ref

Strona 303 - 494 hardware sample

Peak/Valley Change Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions371For more information For more information about triggers, s

Strona 304

MTS MultiPurpose TestWare®Peak/Valley Change Detector ProcessEvent Process Descriptions37212. Optional—Click the Command tab, click a Channel Referenc

Strona 305

Program Event ProcessMTS MultiPurpose TestWare® Event Process Descriptions373Program Event ProcessAbout the Program Event ProcessThe Program Event pro

Strona 306 - Signals tab

MTS MultiPurpose TestWare®Program Event ProcessEvent Process Descriptions374How to detecttransitions after aDone InterruptWhen a procedure or group pr

Strona 307 - Output Units tab

Program Event ProcessMTS MultiPurpose TestWare® Event Process Descriptions375General tabFor more information For more information about triggers, see

Strona 308

MTS MultiPurpose TestWare®Program Event ProcessEvent Process Descriptions376How to Define a Program Event Process1. Drag the icon from the Process P

Strona 309

Periodic Time Event ProcessMTS MultiPurpose TestWare® Event Process Descriptions377Periodic Time Event ProcessAbout the Periodic Time Event ProcessWit

Strona 310 - Cyclic Acquisition Process

MTS MultiPurpose TestWare®Periodic Time Event ProcessEvent Process Descriptions378Periodic Time Event Parameter DescriptionsSettings tab You may type

Strona 311 - Considerations when

Periodic Time Event ProcessMTS MultiPurpose TestWare® Event Process Descriptions379Options tabOptions Tab ITEM DESCRIPTIONTrigger ModeTrigger Once cau

Strona 312 - Data Storage tab

MTS MultiPurpose TestWare®MPT Procedure EditorAbout MultiPurpose TestWare38Tools MenuUse the Tools menu commands to display various editors used to cu

Strona 313

MTS MultiPurpose TestWare®Periodic Time Event ProcessEvent Process Descriptions380General tabFor more informationFor more information about triggers,

Strona 314

Periodic Time Event ProcessMTS MultiPurpose TestWare® Event Process Descriptions381How to Define a Periodic Time Event Process1. Drag the icon from

Strona 315

MTS MultiPurpose TestWare®Failure Detector ProcessEvent Process Descriptions382Failure Detector ProcessAbout the Failure Detector ProcessThe Failure D

Strona 316

Failure Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions383Options tabOptions Tab (part 1 of 2)ITEM DESCRIPTIONLog Message AsAss

Strona 317

MTS MultiPurpose TestWare®Failure Detector ProcessEvent Process Descriptions384General tabActionSpecifies the action that occurs when the process comp

Strona 318

Failure Detector ProcessMTS MultiPurpose TestWare® Event Process Descriptions385Data Destination You set how your acquired data is saved on the Destin

Strona 319 - Fatigue Process

MTS MultiPurpose TestWare®Failure Detector ProcessEvent Process Descriptions38611. In the Name box, type a name for this process. (You can also name t

Strona 320

MTS MultiPurpose TestWare® External Control Process Descriptions387Chapter 15 External Control Process DescriptionsYou use external control processes

Strona 321 - Mean ( ε)

MTS MultiPurpose TestWare®Digital Output ProcessExternal Control Process Descriptions388Digital Output ProcessAbout the Digital Output ProcessThe Digi

Strona 322

Digital Output ProcessMTS MultiPurpose TestWare® External Control Process Descriptions389Keep in mind When you are configuring a Digital Output proces

Strona 323

MPT Procedure EditorMTS MultiPurpose TestWare® About MultiPurpose TestWare39For more information See “Process Palette” on page 84.See “About the MPT O

Strona 324 - Fatigue tab

MTS MultiPurpose TestWare®Digital Output ProcessExternal Control Process Descriptions390Digital Output Parameter DescriptionsOutput table tabOutputs t

Strona 325

Digital Output ProcessMTS MultiPurpose TestWare® External Control Process Descriptions391General tabGeneral TabITEM DESCRIPTIONNameSpecifies the proce

Strona 326 - Monitoring tab

MTS MultiPurpose TestWare®Digital Output ProcessExternal Control Process Descriptions392How to Define a Digital Output Process1. Drag the icon from

Strona 327 - Settings tab

Temperature Control ProcessMTS MultiPurpose TestWare® External Control Process Descriptions393Temperature Control ProcessAbout the Temperature Control

Strona 328

MTS MultiPurpose TestWare®Temperature Control ProcessExternal Control Process Descriptions394Controller options withyour controllerDepending on the ty

Strona 329

Temperature Control ProcessMTS MultiPurpose TestWare® External Control Process Descriptions395Temperature Control Parameter DescriptionsCommand tabCom

Strona 330

MTS MultiPurpose TestWare®Temperature Control ProcessExternal Control Process Descriptions396General tabChannels tabDisplays the channels available to

Strona 331 - Time History Input Process

Temperature Control ProcessMTS MultiPurpose TestWare® External Control Process Descriptions397How to Define a Temperature Control Process1. Drag the

Strona 332 - File tab

MTS MultiPurpose TestWare®Temperature Control ProcessExternal Control Process Descriptions39820. Set the desired Start and Interrupt signals for the p

Strona 333

MTS MultiPurpose TestWare® Other Process Descriptions399Chapter 16 Other Process DescriptionsYou use other processes to perform a variety of miscellan

Strona 334

MTS MultiPurpose TestWare®4Chapter 11 Creating a Practice Test Procedure 153Chapter 12 Command Processes 179Segment Command Process 181Cyclic

Strona 335

MTS MultiPurpose TestWare®MPT Procedure EditorAbout MultiPurpose TestWare40Procedure TableYou use this pane to organize and synchronize the processes

Strona 336 - Trend Process

MTS MultiPurpose TestWare®Program Control ProcessOther Process Descriptions400Program Control ProcessAbout the Program Control ProcessThe Program Cont

Strona 337

Program Control ProcessMTS MultiPurpose TestWare® Other Process Descriptions401Program Control Parameter Descriptions Action tabAction Tab (part 1 of

Strona 338 - Trend Parameter Descriptions

MTS MultiPurpose TestWare®Program Control ProcessOther Process Descriptions402Log Message AsAssigns a severity level to the message (in ascending leve

Strona 339

Program Control ProcessMTS MultiPurpose TestWare® Other Process Descriptions403General tabFor more informationFor more information on Actions, see “Ho

Strona 340

MTS MultiPurpose TestWare®Program Control ProcessOther Process Descriptions404How to Define a Program Control Process1. Drag the icon from the Proce

Strona 341 - How to Define a Trend Process

Group ProcessMTS MultiPurpose TestWare® Other Process Descriptions405Group ProcessAbout the Group ProcessThe Group process is basically a sub-procedur

Strona 342 - About Smart Limits

MTS MultiPurpose TestWare®Group ProcessOther Process Descriptions406Group Process Parameter DescriptionsGeneral tabGeneral TabITEM DESCRIPTIONNameSpec

Strona 343

Group ProcessMTS MultiPurpose TestWare® Other Process Descriptions407How to Define a Group Process1. Drag the icon from the Process Palette to your

Strona 344

MTS MultiPurpose TestWare®MPT Calculation ProcessOther Process Descriptions408MPT Calculation ProcessAbout the MPT Calculations ProcessNote The MPT Ca

Strona 345 - Event Process Descriptions

MPT Calculation ProcessMTS MultiPurpose TestWare® Other Process Descriptions409How to Define the MPT Calculation Process1. Drag the icon from the Pr

Strona 346 - Data Limit Detector Process

MPT Procedure EditorMTS MultiPurpose TestWare® About MultiPurpose TestWare41Procedure TableITEM DESCRIPTIONProcess indicatorsIndicate the status of th

Strona 347 - About Limit Modes

MTS MultiPurpose TestWare®Operator Information ProcessOther Process Descriptions410Operator Information ProcessAbout the Operator Information ProcessT

Strona 348 - Limits tab

Operator Information ProcessMTS MultiPurpose TestWare® Other Process Descriptions411Operator Informationprocess exampleSuppose you want to define an O

Strona 349 - Log Message As

MTS MultiPurpose TestWare®Operator Information ProcessOther Process Descriptions412Operator Information Parameter DescriptionsVariables tabThe Variabl

Strona 350

Operator Information ProcessMTS MultiPurpose TestWare® Other Process Descriptions413Parameters tab Available/IncludedThe Available list displays the v

Strona 351

MTS MultiPurpose TestWare®Operator Information ProcessOther Process Descriptions414 Delete selectionDeletes the selected item. Move selection upMoves

Strona 352

Operator Information ProcessMTS MultiPurpose TestWare® Other Process Descriptions415Note Buffer settings and header options are not available for this

Strona 353 - How to set signal

MTS MultiPurpose TestWare®Operator Information ProcessOther Process Descriptions416Destination tabDestination TabITEM DESCRIPTIONBuffer SizeSpecifies

Strona 354 - Input Table tab

Operator Information ProcessMTS MultiPurpose TestWare® Other Process Descriptions417General tabHow to Define an Operator Information Process without V

Strona 355

MTS MultiPurpose TestWare®Operator Information ProcessOther Process Descriptions41810. Repeat steps 3 - 9 for each item you want to define.11. Click t

Strona 356

Operator Information ProcessMTS MultiPurpose TestWare® Other Process Descriptions4195. If available, click the Parameters tab and define parameters as

Strona 357 - Continuously in step 8

MTS MultiPurpose TestWare®MPT Procedure EditorAbout MultiPurpose TestWare42Process PaletteUse the Process Palette to select test processes by using th

Strona 358

MTS MultiPurpose TestWare®Start Application ProcessOther Process Descriptions420Start Application ProcessAbout the Start Application ProcessWith the S

Strona 359 - Operator Event Process

Start Application ProcessMTS MultiPurpose TestWare® Other Process Descriptions421Start Application Parameter DescriptionsSettings tabSettings Tab (par

Strona 360

MTS MultiPurpose TestWare®Start Application ProcessOther Process Descriptions422Arguments (continued)Argument Syntax Requirements:When you type argume

Strona 361 - Options tab

Start Application ProcessMTS MultiPurpose TestWare® Other Process Descriptions423General tabWait for application to completeWhen enabled, the process

Strona 362

MTS MultiPurpose TestWare®Start Application ProcessOther Process Descriptions424Start Application Process ExampleTo display the contents of the “speci

Strona 363

Start Application ProcessMTS MultiPurpose TestWare® Other Process Descriptions425How to Define the Start Application Process1. Drag the icon from th

Strona 364

MTS MultiPurpose TestWare®Send Mail ProcessOther Process Descriptions426Send Mail ProcessAbout the Send Mail ProcessThe Send Mail process allows you t

Strona 365

Send Mail ProcessMTS MultiPurpose TestWare® Other Process Descriptions427Servers tab Configure server settings on this tab. You may need to contact yo

Strona 366

MTS MultiPurpose TestWare®Send Mail ProcessOther Process Descriptions428How to Define the Send Mail Process1. Drag the icon from the Process Palette

Strona 367

Send Mail ProcessMTS MultiPurpose TestWare® Other Process Descriptions42918. Optional—In the Counter Type list, click a counter type.19. Optional—If y

Strona 368 - Tab (part 1 of 2)

MTS MultiPurpose TestWare® Performing Common Tasks43Chapter 6 Performing Common TasksContents How to Start MultiPurpose TestWare 44How to Display t

Strona 369 - Tab (part 2 of 2)

MTS MultiPurpose TestWare®Set Controller Value ProcessOther Process Descriptions430Set Controller Value ProcessAbout the Set Controller Value ProcessT

Strona 370

Set Controller Value ProcessMTS MultiPurpose TestWare® Other Process Descriptions431Process execution When the process is triggered, the calculation p

Strona 371

MTS MultiPurpose TestWare®Set Controller Value ProcessOther Process Descriptions432Set Controller Value Process Parameter DescriptionsCalc Parameters

Strona 372 - Continuously in step 10

Set Controller Value ProcessMTS MultiPurpose TestWare® Other Process Descriptions433General tabHow to Define the Set Controller Value ProcessSmall cal

Strona 373 - Program Event Process

MTS MultiPurpose TestWare®Set Controller Value ProcessOther Process Descriptions4343. Set the desired Start and Interrupt signals for the process in t

Strona 374 - Done Interrupt

Set Controller Value ProcessMTS MultiPurpose TestWare® Other Process Descriptions4358. Optional—If an MPT variable is assigned in the Value to Set tex

Strona 375

MTS MultiPurpose TestWare®Auto Offset ProcessOther Process Descriptions436Auto Offset ProcessAbout the Auto Offset ProcessThe Auto Offset process allo

Strona 376

Auto Offset ProcessMTS MultiPurpose TestWare® Other Process Descriptions437About Feedback Signal OffsetThe Auto Offset control in the Station Manager

Strona 377 - Periodic Time Event Process

MTS MultiPurpose TestWare®Auto Offset ProcessOther Process Descriptions438Auto Offset Parameter DescriptionsSignals tab Displays the channels availabl

Strona 378

Auto Offset ProcessMTS MultiPurpose TestWare® Other Process Descriptions439How to Define the Auto Offset Process1. Drag the icon from the Process Pa

Strona 379

MTS MultiPurpose TestWare®How to Start MultiPurpose TestWarePerforming Common Tasks44How to Start MultiPurpose TestWareFrom Station Manager To start t

Strona 380

MTS MultiPurpose TestWare®Data Display ProcessOther Process Descriptions440Data Display ProcessAbout the Data Display ProcessThe Data Display process

Strona 381 - in step 6

Data Display ProcessMTS MultiPurpose TestWare® Other Process Descriptions441Data Display Parameter DescriptionsPlots tab This window lets you create,

Strona 382 - Failure Detector Process

MTS MultiPurpose TestWare®Data Display ProcessOther Process Descriptions442Click each tab to access a different set of plot parameters.Plot Setup Tab

Strona 383 - Tab (part 1 of 2)

Data Display ProcessMTS MultiPurpose TestWare® Other Process Descriptions443Signals of Dimension/Included on PlotDisplays signals on the plot with uni

Strona 384 - Tab (part 2 of 2)

MTS MultiPurpose TestWare®Data Display ProcessOther Process Descriptions444Options SubtabLets you define visual characteristics of the plot and buffer

Strona 385

Data Display ProcessMTS MultiPurpose TestWare® Other Process Descriptions445Decimation OptionDecimation refers to discarding a portion of the data in

Strona 386

MTS MultiPurpose TestWare®Data Display ProcessOther Process Descriptions446Reduced Rate—This option causes the buffer to accept acquired data until it

Strona 387 - Chapter 15

Data Display ProcessMTS MultiPurpose TestWare® Other Process Descriptions447Discard Oldest Points—This option causes the buffer to accept acquired dat

Strona 388 - Digital Output Process

MTS MultiPurpose TestWare®Data Display ProcessOther Process Descriptions448Keep 10 Points Per Decade—This option causes the buffer to accept acquired

Strona 389

Data Display ProcessMTS MultiPurpose TestWare® Other Process Descriptions449Acquisition tab This window lets you select the method with which the proc

Strona 390 - Outputs tab

Considerations for Test Design and ExecutionMTS MultiPurpose TestWare® Performing Common Tasks45Considerations for Test Design and ExecutionUndesirabl

Strona 391

MTS MultiPurpose TestWare®Data Display ProcessOther Process Descriptions450Acquisition Method:Level CrossingThe Level Crossing Acquisition Method acqu

Strona 392

Data Display ProcessMTS MultiPurpose TestWare® Other Process Descriptions451General tabGeneral TabITEM DESCRIPTIONNameSpecifies the process name displ

Strona 393 - Temperature Control Process

MTS MultiPurpose TestWare®Data Display ProcessOther Process Descriptions452Additional Plot PropertiesAccessing theProperties and PrintmenuWhen you rig

Strona 394

Data Display ProcessMTS MultiPurpose TestWare® Other Process Descriptions453How to Work with the Data Display ProcessData DisplaycharacteristicsThis p

Strona 395

MTS MultiPurpose TestWare®Data Display ProcessOther Process Descriptions454B. Select a Units type for the Level Increment. C. Type the desired value f

Strona 396

Data Display ProcessMTS MultiPurpose TestWare® Other Process Descriptions45532. In the Name box, type a name for this process. (You can also name the

Strona 397

MTS MultiPurpose TestWare®Data Display ProcessOther Process Descriptions456

Strona 398

MTS MultiPurpose TestWare® Trend and Fatigue Monitoring Applications457Chapter 17 Trend and Fatigue Monitoring ApplicationsContents Model 793.12 Trend

Strona 399 - Other Process Descriptions

MTS MultiPurpose TestWare®Model 793.12 Trend Monitoring ApplicationTrend and Fatigue Monitoring Applications458Model 793.12 Trend Monitoring Applicati

Strona 400 - Program Control Process

Model 793.12 Trend Monitoring ApplicationMTS MultiPurpose TestWare® Trend and Fatigue Monitoring Applications459Trend Monitoring Control PanelWith the

Strona 401 - Action tab

MTS MultiPurpose TestWare®Considerations for Test Design and ExecutionPerforming Common Tasks46Design elements thatmay lock up yoursystemYou can inadv

Strona 402

MTS MultiPurpose TestWare®Model 793.12 Trend Monitoring ApplicationTrend and Fatigue Monitoring Applications460Trend Monitoring WindowThe Trend Monito

Strona 403

Model 793.12 Trend Monitoring ApplicationMTS MultiPurpose TestWare® Trend and Fatigue Monitoring Applications461Controls The Trend Monitoring main win

Strona 404

MTS MultiPurpose TestWare®Model 793.12 Trend Monitoring ApplicationTrend and Fatigue Monitoring Applications462Context menu Other commands are availab

Strona 405 - Group Process

Model 793.12 Trend Monitoring ApplicationMTS MultiPurpose TestWare® Trend and Fatigue Monitoring Applications463Limit Settings WindowAll limit adjustm

Strona 406

MTS MultiPurpose TestWare®Model 793.12 Trend Monitoring ApplicationTrend and Fatigue Monitoring Applications464Numerical Data WindowThis Numerical Dat

Strona 407 - How to Define a Group Process

Model 793.14 Fatigue Monitoring ApplicationMTS MultiPurpose TestWare® Trend and Fatigue Monitoring Applications465Model 793.14 Fatigue Monitoring Appl

Strona 408 - MPT Calculation Process

MTS MultiPurpose TestWare®Model 793.14 Fatigue Monitoring ApplicationTrend and Fatigue Monitoring Applications466Fatigue Monitoring Control PanelITEM

Strona 409

Model 793.14 Fatigue Monitoring ApplicationMTS MultiPurpose TestWare® Trend and Fatigue Monitoring Applications467Fatigue Monitoring WindowThe Fatigue

Strona 410 - Operator Information Process

MTS MultiPurpose TestWare®Model 793.14 Fatigue Monitoring ApplicationTrend and Fatigue Monitoring Applications468Controls The Fatigue Monitoring main

Strona 411

Model 793.14 Fatigue Monitoring ApplicationMTS MultiPurpose TestWare® Trend and Fatigue Monitoring Applications469Context menu Other commands are avai

Strona 412 - Variables tab

How to Open a ProcedureMTS MultiPurpose TestWare® Performing Common Tasks47How to Open a Procedure1. From the MPT control panel (or from the MPT Proce

Strona 413 - Parameters tab

MTS MultiPurpose TestWare®Model 793.14 Fatigue Monitoring ApplicationTrend and Fatigue Monitoring Applications470Limit Settings WindowAll limit adjust

Strona 414

Model 793.14 Fatigue Monitoring ApplicationMTS MultiPurpose TestWare® Trend and Fatigue Monitoring Applications471About Best Case/Worst CaseThe terms

Strona 415

MTS MultiPurpose TestWare®Model 793.14 Fatigue Monitoring ApplicationTrend and Fatigue Monitoring Applications472Numerical Data WindowThe Numerical Da

Strona 416

MTS MultiPurpose TestWare® Model 793.11 Profile Editor473Chapter 18 Model 793.11 Profile EditorAbout the ProfileEditorAbout the Profile Editor 476A

Strona 417

MTS MultiPurpose TestWare®Model 793.11 Profile Editor474Block-Arbitrary Profile Example 503Graphical Preview Channel 1 504Graphical Preview Chan

Strona 418

MTS MultiPurpose TestWare® Model 793.11 Profile Editor475Actions Window 541Channel Menu 542Tools Menu 542About Graphical Preview Window 54

Strona 419

MTS MultiPurpose TestWare®Profile EditorModel 793.11 Profile Editor476Profile EditorAbout the Profile EditorWith the Profile Editor application you ca

Strona 420 - Start Application Process

Profile EditorMTS MultiPurpose TestWare® Model 793.11 Profile Editor477Note The Profile Editor’s graphical display will not display the tapered wavefo

Strona 421

MTS MultiPurpose TestWare®Profile EditorModel 793.11 Profile Editor478For more information See “About Graphical Preview Window” on page 543.About Prof

Strona 422

Profile EditorMTS MultiPurpose TestWare® Model 793.11 Profile Editor479A single profile can (and often does) contain the command content of an entire

Strona 423

MTS MultiPurpose TestWare®How to Run a ProcedurePerforming Common Tasks48How to Run a ProcedureRunning a procedure begins with station preparation and

Strona 424

MTS MultiPurpose TestWare®Profile EditorModel 793.11 Profile Editor480The file is read in sequence (row by row) to produce a waveform:Note The first s

Strona 425

Profile EditorMTS MultiPurpose TestWare® Model 793.11 Profile Editor481About Playing Out ProfilesTo play out a profile, you must first import it into

Strona 426 - Send Mail Process

MTS MultiPurpose TestWare®Profile EditorModel 793.11 Profile Editor482Profiles are saved in the ASCII format.You can also specify how you want the pro

Strona 427

Profile EditorMTS MultiPurpose TestWare® Model 793.11 Profile Editor483About Profile TypesYou can create two types of profiles with the Profile Editor

Strona 428

MTS MultiPurpose TestWare®Profile EditorModel 793.11 Profile Editor484About segments The first segment in a row begins at the current level and travel

Strona 429 - Procedure table

Profile EditorMTS MultiPurpose TestWare® Model 793.11 Profile Editor485With a phase profile, you do not specify the timing of channels independently.

Strona 430 - Set Controller Value Process

MTS MultiPurpose TestWare®Profile EditorModel 793.11 Profile Editor486Assign ProfileconstantsYou can set parameters of each channel grid to be constan

Strona 431

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor487Creating ProfilesHow to Start the Profile EditorFrom the desktop From the de

Strona 432 - Values tab

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor488Using ShortcutsYou can use a shortcut to automatically load a specific profil

Strona 433

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor4894. On the Edit menu, select Constants and define the Channel Constants windo

Strona 434

About CountersMTS MultiPurpose TestWare® Performing Common Tasks492. Start your test.On the Station Controls panel click the run button to start the t

Strona 435

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor490How to Create Block Arbitrary ProfilesThis section contains step-by-step inst

Strona 436 - About the Auto Offset Process

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor491See “How to Preview Profiles” on page 513.See “How to Analyze Profiles” on p

Strona 437 - About Feedback Signal Offset

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor492Note When you type a value into a cell, it will take effect when you press th

Strona 438

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor493How to Assign ActionsDefine actions 1. On the Edit menu, select Actions.2. O

Strona 439 - Available list

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor494How to Analyze Profiles1. On the Too ls menu, select Analyze. 2. The Profile

Strona 440 - Data Display Process

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor495Design ConsiderationsProfile Design ConsiderationsThere are several design c

Strona 441 - Data display plot setup

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor496A phase profile can define several channels of data. Each row of segment data

Strona 442

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor497Header Data SyntaxThe following is an example of proper header data syntax:F

Strona 443

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor498Action and Counter SyntaxObserve the following syntax requirements when addin

Strona 444

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor499Level1 Actionmm5.0000 <DO Off>-5.0000 “Counter 1”8.0000-8.00002.000 Co

Strona 445 - Decimation

MTS MultiPurpose TestWare® Contents5Peak/Valley Change Detector Process 364Program Event Process 373Periodic Time Event Process 377Failure De

Strona 446

MTS MultiPurpose TestWare®Types of CountersPerforming Common Tasks50Run time counter The Run Time counter displays the elapsed time of the current tes

Strona 447

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor500Channel Data SyntaxFollowing the channel definition, you must define the comm

Strona 448

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor501Rate type A rate type determines the time base of the waveform. Three types

Strona 449

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor502Count The count lets you repeat a cyclic waveform a specific number of times.

Strona 450

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor503See “Shape” on page 502.See “Level data” on page 502.See “Phase lag” on page

Strona 451

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor504Graphical Preview Channel 1Graphical Preview Channel 2

Strona 452 - Additional Plot Properties

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor505Phase Profile ExampleHeader data FileType= PhaseDate= 10-Dec-00Channels= 2Ch

Strona 453 - Data Display

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor506Graphical Preview Channels 1 and 2About Cycle and Segment BehaviorCycle behav

Strona 454 - setting

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor507Segment behavior The first segment in a row begins at the current level and

Strona 455 - Defining additional

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor508The illustration shows that since the first segment in each row is a transiti

Strona 456

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor509Because of this, it is good practice to be aware of all of the instances in

Strona 457 - Chapter 17

How to Display Counters and Status PanelsMTS MultiPurpose TestWare® Performing Common Tasks51Status counters display Elapsed Time (or Distance) and To

Strona 458

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor510Next, select the Multipurpose TestWare application, then open the MPT Procedu

Strona 459 - Active Procedures

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor511Using the same profile, suppose you change the Control Mode selection to for

Strona 460 - Trend Monitoring Window

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor512Using Normalized Dimensions to Define Control ModesIn the Level Units list, s

Strona 461 - Channel Selection

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor513How to Preview ProfilesOn the Too ls menu, select Show Graph. This displays

Strona 462 - ESCRIPTION

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor514TransitionsAbout Adding TransitionsThe first segment (or the first half of th

Strona 463 - Limit Settings Window

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor515This MTS Profile Editor example shows how MPT automatically generates the tr

Strona 464 - Numerical Data Window

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor516About Working with Automatic TransitionsThe following example shows how the P

Strona 465

Creating ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor517About Working with Manual TransitionsSometimes you may want to change the ch

Strona 466

MTS MultiPurpose TestWare®Creating ProfilesModel 793.11 Profile Editor518The plot shows the new frequencies of the added transition segments.1Row 1123

Strona 467 - Fatigue Monitoring Window

How to Play Out ProfilesMTS MultiPurpose TestWare® Model 793.11 Profile Editor519How to Play Out ProfilesAbout Using Profile EditorYou are not require

Strona 468

MTS MultiPurpose TestWare®How to Display Counters and Status PanelsPerforming Common Tasks522. Check the Show Status Panel at Run Time box as desired.

Strona 469

MTS MultiPurpose TestWare®How to Play Out ProfilesModel 793.11 Profile Editor520About Setting Up Profiles in MPTMPT Profile CommandprocessThe Profile

Strona 470

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor521Profile Editor Controls and DisplaysAbout Profile Editor

Strona 471 - About Best Case/Worst Case

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor522Menu BarThe Menu Bar has commands for managing the Station

Strona 472

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor523ToolbarThe toolbar buttons provide quick access to common

Strona 473 - Model 793.11 Profile Editor

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor524File MenuFile MenuITEM DESCRIPTIONNew ProfileDisplays the

Strona 474

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor525New Profile Settings WindowPath File > New Profile...U

Strona 475

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor526Note If you type values that will result in flat spots or

Strona 476 - Profile Editor

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor527Level1 (L1)Level2 (L2)For the first segment in a row, lev

Strona 477

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor528For more information See “Edit Menu” on page 535.See “Anal

Strona 478 - 23 4 5 6

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor529See “How to Define Taper Times” on page 532.See “How to A

Strona 479

About the Clear Counters on Reset FunctionMTS MultiPurpose TestWare® Performing Common Tasks53About the Clear Counters on Reset FunctionWith the Clear

Strona 480 - About Creating Profiles

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor530Sine—Creates sine waves that travel between end levels L1

Strona 481 - About Working with Profiles

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor531Ramp Tapered—Creates triangle waves that travel at 100% a

Strona 482

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor532True Sine Tapered—Creates sine waves that travel at 100% a

Strona 483 - Block-Arbitrary Profiles

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor533Print Preview WindowAccess Toolbar > Print Preview Ico

Strona 484 - Phase Profiles

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor534Profile Summary WindowAccess File > Summary...Use the P

Strona 485 - About Profile Properties

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor535Edit MenuWith the Edit menu you can define the characteri

Strona 486 - About Profile Constants

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor536Channel Setup WindowAccess Edit > Setup...Use the Chann

Strona 487 - Creating Profiles

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor537 Level UnitsDisplays the unit of measurement for the sele

Strona 488 - How to Create New Profiles

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor538Count UnitsAssigns Cycles or Segments as the cyclic units.

Strona 489 - How to Set Preferences

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor539For more information For more information, see “Design Co

Strona 490

MTS MultiPurpose TestWare®About the Clear Counters on Reset FunctionPerforming Common Tasks54Use the right-mousemenu for channelcountersOn the MPT con

Strona 491 - How to Create Phase Profiles

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor540Channel Constants Window (part 1 of 2)ITEM DESCRIPTIONTim

Strona 492

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor541For more information See “Channel Setup Window” on page 5

Strona 493 - How to Assign Actions

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor542Channel MenuWith the Channel menu you can add and remove c

Strona 494 - How to Analyze Profiles

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor543About Graphical Preview WindowAccess Tools > Show Grap

Strona 495 - Design Considerations

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor544Graphical Preview Tab Window (part 2 of 5)ITEM DESCRIPTION

Strona 496

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor545X AxisDefines the characteristics of the x axis (the bott

Strona 497 - Header Data Syntax

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor546Right Y AxisDefines the characteristics of the right y axi

Strona 498 - Action and Counter Syntax

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor547Grid LinesWhen selected, displays grid lines on the graph

Strona 499 - Channel Header Syntax

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor548Analyze WindowAccess Tools > AnalyzeUse the Profile Mes

Strona 500 - Channel Data Syntax

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor549The application would detect that the Level 1 values in R

Strona 501 - EYWORD RANGE COMMENTS

About Working with Unit Assignment Set EditorMTS MultiPurpose TestWare® Performing Common Tasks55About Working with Unit Assignment Set EditorUse the

Strona 502

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor550Window MenuUse the Window menu commands to change the appe

Strona 503 - Channel 2 data

Profile Editor Controls and DisplaysMTS MultiPurpose TestWare® Model 793.11 Profile Editor551Help MenuWith the Help menu you can display version infor

Strona 504 - Graphical Preview Channel 2

MTS MultiPurpose TestWare®Profile Editor Controls and DisplaysModel 793.11 Profile Editor552

Strona 505 - Phase Profile Example

About Default TemplatesMTS MultiPurpose TestWare® Default Templates553Appendix 19Default TemplatesAbout Default TemplatesWhen you create a new test pr

Strona 506

MTS MultiPurpose TestWare®How to Use Multiple Default TemplatesDefault Templates5547. From the MPT file icon pull-down menu, click Save Procedure to s

Strona 507 - Segment Count of 1

Template Error MessagesMTS MultiPurpose TestWare® Default Templates555When you start MPT The following message is displayed when you start the MPT app

Strona 508

MTS MultiPurpose TestWare®Template Error MessagesDefault Templates556

Strona 509

About The MTS Excel File ConverterMTS MultiPurpose TestWare® Excel File Converter557Appendix 20Excel File ConverterAbout The MTS Excel File ConverterT

Strona 510

MTS MultiPurpose TestWare®How to Install the Excel File ConverterExcel File Converter558How to Install the Excel File ConverterThe Excel File Converte

Strona 511

How to Use the Excel File ConverterMTS MultiPurpose TestWare® Excel File Converter559Note Smart processing will recognize German or French equivalents

Strona 512

MTS MultiPurpose TestWare®About Working with Unit Assignment Set EditorPerforming Common Tasks56Standard unit sets CGSSET - Centimeters-Grams-Seconds—

Strona 513 - How to Preview Profiles

MTS MultiPurpose TestWare®Excel File Converter TroubleshootingExcel File Converter560

Strona 514 - Transitions

MTS MultiPurpose TestWare® MPT Shortcuts561Appendix 21MPT ShortcutsYou can use an MPT shortcut to perform a number of tasks automatically when you sta

Strona 515

MTS MultiPurpose TestWare®Shortcut Command LineMPT Shortcuts562Shortcut Command LineNote The syntax of the shortcut command lines are critical. If you

Strona 516 - 1, segment 1)

Shortcut Command LineMTS MultiPurpose TestWare® MPT Shortcuts563About the /EditOnlycommandThe /EditOnly option will launch MPT as an editor only. When

Strona 517

MTS MultiPurpose TestWare®How to Create an MPT ShortcutMPT Shortcuts564Likewise, if you inadvertently type negative values for width or height, MPT wi

Strona 518

How to Edit the Shortcut Command LineMTS MultiPurpose TestWare® MPT Shortcuts565How to Edit the Shortcut Command LineEdit the shortcut command line to

Strona 519 - How to Play Out Profiles

MTS MultiPurpose TestWare®How to Edit the Shortcut Command LineMPT Shortcuts566

Strona 520 - MPT Profile Command

MTS MultiPurpose TestWare® Index567IndexSymbols"Make" tool 115AAbsolute Error signal in DAQ processes 277actionchannel grid 527action consta

Strona 521

MTS MultiPurpose TestWare®Index568Control Panel 22, 23control panel 23controller rates supported by the Time History Output process 248control-mode va

Strona 522 - Menu Bar

MTS MultiPurpose TestWare® Index569Group process 405about interrupts 100how to move between the group and the main procedure windows 405start and inte

Strona 523

About the MPT Specimen LogMTS MultiPurpose TestWare® Performing Common Tasks57About the MPT Specimen LogUse the MPT Specimen Log to display a record o

Strona 524 - File Menu

MTS MultiPurpose TestWare®Index570Numerical Data window 464, 472Ooffset considerations 437open existing profiles 489Operator Event process 359how to d

Strona 525 - Channel Grid Display

MTS MultiPurpose TestWare® Index571Preview tabAuto Scale 545Available Channels 543Channel Display 543Channels to Plot 543description 543grid lines 547

Strona 526

MTS MultiPurpose TestWare®Index572Send Mail Now button 426Send Mail process 426Sensor signals 277Sequence Counters 22sequencing processesexample 93Set

Strona 527 - Action (Optional)

MTS MultiPurpose TestWare® Index573Trend processabout data handling 336about RMS, variance, and asymmetric full scales 343about smart limits 342how to

Strona 528

MTS MultiPurpose TestWare®Index574

Strona 530

mMTS Systems Corporation14000 Technology DriveEden Prairie, Minnesota 55344-2290 USAToll Free Phone: 800-328-2255 (within the U.S. or Canada)Phone: 95

Strona 531

MTS MultiPurpose TestWare®About the MPT Specimen LogPerforming Common Tasks58Archived log files are named specimen000.log, specimen001.log, specimen00

Strona 532 - How to Define Taper Times

About the MPT Specimen LogMTS MultiPurpose TestWare® Performing Common Tasks59Closes the selected MPT Specimen Log and removes the log from the Log li

Strona 533 - Print Preview Toolbar

MTS MultiPurpose TestWare®6How to Play Out Profiles 519Profile Editor Controls and Displays 521Appendix 19 Default Templates 553Appendix 20 E

Strona 534 - Profile Summary Window

MTS MultiPurpose TestWare®About the MPT Specimen LogPerforming Common Tasks60For more information See “About Counters” on page 49.For information abou

Strona 535 - Edit Menu

MTS MultiPurpose TestWare® MPT Options Editor61Chapter 7 MPT Options EditorContents About the MPT Options Editor 62MPT Options Editor Execution Tab

Strona 536 - Channel Setup Window

MTS MultiPurpose TestWare®About the MPT Options EditorMPT Options Editor62About the MPT Options EditorUse the MPT Options Editor to set preferences th

Strona 537 - Level Units

MPT Options Editor Execution TabMTS MultiPurpose TestWare® MPT Options Editor63Options that are controlled from the Execution tab include:• How the sy

Strona 538

MTS MultiPurpose TestWare®MPT Options Editor Execution TabMPT Options Editor64Required PowerSpecifies the hydraulic pressure setting required by the c

Strona 539 - Channel Constants Window

MPT Options Editor Execution TabMTS MultiPurpose TestWare® MPT Options Editor65For more information For more information, see “MPT Run/Stop/Hold Panel

Strona 540

MTS MultiPurpose TestWare®About Setpoint Use with MPT Test ProceduresMPT Options Editor66About Setpoint Use with MPT Test ProceduresGeneralconsiderati

Strona 541 - Actions Window

About Command Hold and Stop BehaviorsMTS MultiPurpose TestWare® MPT Options Editor67If you want to run your test procedure on a station that has a dua

Strona 542 - Channel Menu

MTS MultiPurpose TestWare®About Data Acquisition Resulting From Command MPT Options Editor68About Data Acquisition Resulting From Command Stop Behavio

Strona 543 - Access Tools > Show Graph

About Command Stop Behaviors and AutomaticMTS MultiPurpose TestWare® MPT Options Editor69About Command Stop Behaviors and Automatic Setpoint Adjustmen

Strona 544 - DESCRIPTION

MTS MultiPurpose TestWare® Technical Support7Technical SupportHow to Get Technical SupportStart with yourmanualsThe manuals supplied by MTS provide mo

Strona 545

MTS MultiPurpose TestWare®About Transition StatesMPT Options Editor70About Transition StatesOf the seven test states in MPT, there are four Entering a

Strona 546

About Transition StatesMTS MultiPurpose TestWare® MPT Options Editor71The amount of time the test remains in a state also results from the time you ha

Strona 547 - Grid Lines

MTS MultiPurpose TestWare®About Transition StatesMPT Options Editor72User ActionsFor more information See “About Command Hold and Stop Behaviors” on p

Strona 548 - Analyze Window

MPT Options Editor Specimen TabMTS MultiPurpose TestWare® MPT Options Editor73MPT Options Editor Specimen TabUse the Specimen tab to determine the sto

Strona 549

MTS MultiPurpose TestWare®MPT Options Editor Recovery TabMPT Options Editor74MPT Options Editor Recovery TabUse the Recovery tab to determine how ofte

Strona 550 - Window Menu

About Test RecoveryMTS MultiPurpose TestWare® MPT Options Editor75The snapshots of the test state and status can be used to restart a test that was in

Strona 551 - Help Menu

MTS MultiPurpose TestWare®About Test RecoveryMPT Options Editor76What is not saved When you recover a test, the test status is restored to the point w

Strona 552

MPT Options Editor Specimen Log TabMTS MultiPurpose TestWare® MPT Options Editor77MPT Options Editor Specimen Log TabUse the Specimen Log tab on the M

Strona 553 - Default Templates

MTS MultiPurpose TestWare®MPT Options Editor Specimen Log TabMPT Options Editor78• Fatal Error—Writes only Fatal Error messages; does not write Diagno

Strona 554 - Template Error Messages

MPT Options Editor Control Panel TabMTS MultiPurpose TestWare® MPT Options Editor79MPT Options Editor Control Panel TabUse the Control Panel tab to sp

Strona 555

MTS MultiPurpose TestWare®Technical Support8Before You Contact MTSMTS can help you more efficiently if you have the following information available wh

Strona 556

MTS MultiPurpose TestWare®MPT Options Editor Properties TabMPT Options Editor80For more information See “MPT Test Progress Panel” on page 28.See “MPT

Strona 557 - Excel File Converter

MPT Options Editor Unit Selection TabMTS MultiPurpose TestWare® MPT Options Editor81You can type a process summary, identify the procedure, describe t

Strona 558

MTS MultiPurpose TestWare®MPT Options Editor Unit Selection TabMPT Options Editor82For more information See “About Default Templates” on page 553.Use

Strona 559

MTS MultiPurpose TestWare® Working with MPT Processes83Chapter 8 Working with MPT ProcessesContents About MPT Processes 84Process Palette 84How

Strona 560

MTS MultiPurpose TestWare®About MPT ProcessesWorking with MPT Processes84About MPT ProcessesWhen you create tests with the MPT application, you use MP

Strona 561 - MPT Shortcuts

How to Add Processes to the Procedure TableMTS MultiPurpose TestWare® Working with MPT Processes85How to Add Processes to the Procedure TableThe first

Strona 562 - Shortcut Command Line

MTS MultiPurpose TestWare®How to Select Processes in Procedure TablesWorking with MPT Processes86How to Select Processes in Procedure TablesYou may wa

Strona 563

About Cutting, Copying, and Pasting ProcessesMTS MultiPurpose TestWare® Working with MPT Processes87About Cutting, Copying, and Pasting ProcessesYou c

Strona 564 - How to Create an MPT Shortcut

MTS MultiPurpose TestWare®About Sequencing ProcessesWorking with MPT Processes88In your procedure or group table:• Use the trigger signals available i

Strona 565

About “Buffer Full” SignalsMTS MultiPurpose TestWare® Working with MPT Processes89Conversely, you can use the <Procedure.Start>, or a single don

Strona 566

MTS MultiPurpose TestWare® Technical Support9Know relevantcomputer informationFor a computer problem, have the following information available:• Manuf

Strona 567

MTS MultiPurpose TestWare®About “Trigger” SignalsWorking with MPT Processes90When buffer fullsignals are sentIf you do not specify the number of sampl

Strona 568 - 252, 264

About “Trigger” SignalsMTS MultiPurpose TestWare® Working with MPT Processes91Trigger signal example The following sample procedure makes use of a tri

Strona 569

MTS MultiPurpose TestWare®About “Trigger” SignalsWorking with MPT Processes92Procedure diagram The diagram below illustrates the connections between t

Strona 570

Process Sequence ExampleMTS MultiPurpose TestWare® Working with MPT Processes93Process Sequence ExampleAssume when you start your test you want the pr

Strona 571

MTS MultiPurpose TestWare®About Editing Trigger SignalsWorking with MPT Processes94About Editing Trigger SignalsProcedure and group tables that are po

Strona 572

How to Set/Edit the Interrupt SignalMTS MultiPurpose TestWare® Working with MPT Processes95How to Set/Edit the Interrupt Signal1. To specify the inter

Strona 573

MTS MultiPurpose TestWare®Example of Sequencing a Single ProcessWorking with MPT Processes96Example of Sequencing a Single Process The procedure shown

Strona 574

Example of Sequencing Multiple ProcessesMTS MultiPurpose TestWare® Working with MPT Processes97Example of Sequencing Multiple ProcessesThe window belo

Strona 575

MTS MultiPurpose TestWare®About Sequencing Group ProcessesWorking with MPT Processes98About Sequencing Group ProcessesA Group process is basically a s

Strona 576

How to Open the Group TableMTS MultiPurpose TestWare® Working with MPT Processes99How to Open the Group TableMethod 1 Click the Group process icon in

Komentarze do niniejszej Instrukcji