Models FlexTest® IIm/GT/SE Controller Hardware
Analog I/O Connections
FlexTest GT Controller Connections
118
Cable specification The cable specifications apply to both the analog inputs and analog outputs.
The cable from the front panel of the I/O Carrier module has the following
specification:
15-contact type D male EMI connector.
Backshell–EMI metallized plastic.
Cable type–up to 6 shielded twisted pairs, each with the drain wire
connected to the signal source.
The cable to the Ch 1 - Ch 6 connectors on the rear panel have the following
specifications:
BNC connector UG88/U
Cable–RG-58 coaxial
Use of a smaller coaxial cable and a RG-174 BNC connector with an
appropriate cable end is permissible.