7. Verify that the FieldPoint has been configured properly and data acquisition
is functioning.
A. Expand Data Neighborhood down to FP Res.
B. Click (select) FP-SG-140@1.
C. Click Start.
D. Verify that Range and Timestamp values are being recorded. If all
strain gages are being used, all Status checks should be successful. If
some of the strain gages are not being used, the status might be out of
range.
E. Click Stop.
F. Repeat steps C through E for FP-SG-140@2 and FP-AI-110@3.
A
B
C
D
E
F
Przeglądanie stron 56