Mts Model 512-04 Hydraulic Power Unit Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Mts Model 512-04 Hydraulic Power Unit. MTS Model 512-04 Hydraulic Power Unit User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Product Information

Model 512.04 Hydraulic Power UnitProduct Information l 015-206-401 C

Strona 2 - UBLICATION

Model 512.04 Hydraulic Power Unit 10 Introduction Specifications Model 512.04 SpecificationsP ARAMETER S PECIFICATION EnvironmentalOperating temperatu

Strona 3 - Contents

Model 512.04 Hydraulic Power Unit Introduction 11 Dimensions The following figure shows those dimensions which are useful when installing the hydrauli

Strona 4

Model 512.04 Hydraulic Power Unit 12 Introduction

Strona 5

Model 512.04 Hydraulic Power Unit Installation 13 Installation Perform the following to install the Model 512.04 Hydraulic Power Unit. 1. Position th

Strona 6 - Functional Description

Model 512.04 Hydraulic Power Unit 14 Installation 2. Connect the hydraulic lines. See “Connection Locations” on page 13 to determine the locations of

Strona 7 - Hydraulic

Model 512.04 Hydraulic Power Unit Installation 15Electrical SchematicRemoteEmergencyStop SwitchCPC-14S1381 ARemove Jumper ifRemote Emergency StopSwi

Strona 8 - Component Identification

Model 512.04 Hydraulic Power Unit 16 Installation

Strona 9 - Air-Cooled

Model 512.04 Hydraulic Power Unit Operation 17 Operation The following procedure is a guideline, and it assumes you are starting the hydraulic power

Strona 10 - Specifications

Model 512.04 Hydraulic Power Unit 18 Operation 3. At your test controller, make sure hydraulic pressure is turned off. NOTE Some controllers can rem

Strona 11 - Dimensions

Model 512.04 Hydraulic Power Unit Operation197. Run the HPU for 20–30 minutes to get the hydraulic fluid up to operating temperature of 64–68°C (147–15

Strona 12 - Introduction

Copyright information © 2000 MTS Systems Corporation. All rights reserved. Trademark information MTS is a registered trademark of MTS Systems Corpora

Strona 13 - Installation

Model 512.04 Hydraulic Power Unit20Operation

Strona 14 - ONNECTOR

Model 512.04 Hydraulic Power Unit Maintenance21MaintenanceContents Reducing the Fluid Temperature 22Adjusting the Air Flow 23Adjusting the Water

Strona 15 - Electrical Schematic

Model 512.04 Hydraulic Power Unit22MaintenanceReducing the Fluid Temperature The hydraulic power unit (HPU) will be shut down if the hydraulic fluid re

Strona 16

Model 512.04 Hydraulic Power Unit Maintenance23Adjusting the Air FlowAir-cooled heat exchangers use louvers to control airflow through the exchanger. Y

Strona 17 - Operation

Model 512.04 Hydraulic Power Unit24MaintenanceAdjusting the Water Flow On water-cooled heat exchangers, the water control valve regulates the flow of w

Strona 18

Model 512.04 Hydraulic Power Unit Maintenance25Adding Hydraulic Fluid1. The hydraulic power unit (HPU) will shut down when fluid drops below the sight

Strona 19

Model 512.04 Hydraulic Power Unit26MaintenanceResetting the Thermal OverloadsThe thermal overloads of the hydraulic power unit (HPU) can be tripped by

Strona 20

Model 512.04 Hydraulic Power Unit Maintenance27Changing the Output PressureThe hydraulic power unit (HPU) comes with its output pressure set at 13.8 M

Strona 21 - Maintenance

Model 512.04 Hydraulic Power Unit28Maintenance1. Set the HPU’s output to HIGH PRESS. Put the HPU into a no-flow condition (where no fluid is flowing to o

Strona 22

Model 512.04 Hydraulic Power Unit Maintenance29Lubricating the MotorThis pump’s motor bearing of the hydraulic power supply (HPU) needs lubrication ev

Strona 23 - Adjusting the Air Flow

Model 512.04 Hydraulic Power Unit Contents 3 Contents Contents 3 Introduction 5 Functional Description 6Component Identification 8Specifica

Strona 24 - Adjusting the Water Flow

Model 512.04 Hydraulic Power Unit30MaintenanceChanging the FilterChange the filter whenever the filter change gage’s needle stays in the yellow or red z

Strona 25 - Adding Hydraulic Fluid

Model 512.04 Hydraulic Power Unit Maintenance31Changing the Hydraulic FluidAs part of your regular HPU maintenance, change the hydraulic fluid every 25

Strona 26

Model 512.04 Hydraulic Power Unit32MaintenanceComponent LocationsSynasol is toxic and flammable.Use the Synasol solvent in a ventilated area and keep i

Strona 27 - Changing the Output Pressure

Model 512.04 Hydraulic Power Unit Maintenance333. Clean the reservoir.A. Disconnect the heat exchanger’s two hydraulic fluid lines.B. Unscrew the cover

Strona 29 - Lubricating the Motor

mMTS Systems Corporation14000 Technology DriveEden Prairie, Minnesota 55344-2290 USAToll Free Phone: 800-328-2255(within the U.S. or Canada)Phone: 952

Strona 30 - Changing the Filter

Model 512.04 Hydraulic Power Unit 4 Contents

Strona 31 - Changing the Hydraulic Fluid

Model 512.04 Hydraulic Power Unit Introduction 5 Introduction Contents Functional Description 6Component Identification 8Specifications 10 Thi

Strona 32 - Component Locations

Model 512.04 Hydraulic Power Unit 6 Introduction Functional Description The hydraulic power unit (HPU) is the mechanical source of high-pressure hydr

Strona 33

Model 512.04 Hydraulic Power Unit Introduction 7 Electronics The HPU has basic controls to turn it on to low pressure or high pressure and to turn it

Strona 34

Model 512.04 Hydraulic Power Unit 8 Introduction Component Identification This table describes the components shown in the figure on page 9. Component

Strona 35

Model 512.04 Hydraulic Power Unit Introduction 9Major ComponentsPump MotorControl BoxFilter Change GageFilterHeat ExchangerSight Glass Pressure Gage

Komentarze do niniejszej Instrukcji

Brak uwag